- Home
- »
- Products & Services
- »
- Fire Safety System 1
Fire Safety System 1
Addressable & Conventional Manual Call Point
Usage/Application | Fire Alarm System |
Weight | 100-200g |
Material | ABS, PC (transparent part) |
Usage | Fire alarm or access control |
Type | Addressable & Conventional Manual Call |
SYSYTEM SENSOR COVENTIONAL MULTI-CRITERIA DETECTOR
Material | PC/ABS |
Sensor Type | Photoelectric Smoke Detector |
Usage/Application | Industrial Premises |
Brand | SYSTEM SENSOR |
Model Name/Number | System Sensor 22051TE-26 |
Weight | 99g (inc base |
Color | white |
The multi-criteria multi-sensor 22051TE Photo Thermal detector uses thermal assistance to the core photoelectric smoke detector to give enhanced false alarm immunity and faster response to a wide range of incipient fires.
The plug-in unit combines two separate sensing elements that are managed by embedded software to act as a single unit. The 22051TE conforms to EN54-5, a 58°C fixed temperature and rate of rise thermal, with the smoke detection element conforming to EN54-7.
Simplex Addressable Manual Call Point
Dimensions Mm | 5 x 5 x 5 in |
Color | Red |
Weight | .25 lbs |
Type | Addressable |
Model Name/Number | Simplex (4099-9006) |
Hochiki Addressable Manual Call Point
Usage/Application | Fire Alarm System |
Model Name/Number | HCP-W(SCI) |
Working Voltage | 17 - 41 VDC |
System Components | heat detetor |
Type | Addressable |
Automation Grade | Automatic |
Description Model HCP-W(SCI) is a weatherproof Manual Call Point with integral short-circuit isolator, which is fully compatible with Hochiki’s ESP analogue addressable protocol. The unit incorporates a bi-coloured LED, which can be selected as pulsing/non-pulsing*1 for communications polling and is continuously lit when the HCP-W(SCI) is operated – in these two states the LED will show red. The LED will show amber when a short-circuit is present but will switch to red if the unit is activated. The unit operates by pressing the EN54 compliant non-frangible (plastic) element and produces a high level ESP interrupt. A built in test function initiated by the control panel ensures the integrity of the device at all times and the device can be tested by insertion of a test key in the underside of the unit. Two terminal blocks are provided for easy connection to the loop wiring. The unit is addressed using the TCH-B100 Hand Held Programmer for quick and reliable addressing. An optional glass element is also available.
Morley Honeywell Addressable Manual Call Point
Model Name/Number | MI-MCP Series |
Dimensions Mm | 89 x 93 x 59.5 mm |
Weight | Semi Flush 110g,Surface 160g |
Operating Temperature | -30 to +70 Deg C |
Working Voltage | 15V to 30Vdc max |
Usage/Application | Fire Alarm System |
Features:
1.Unique ‘Plug & Play’ installation concept
2.Re-settable operating element option
3.Analogue addressable communications 4.Fully compliant with EN54, Part 11 5.Backward compatibility
6.Enhanced aesthetics
7.Integral LED
8.Integral loop isolation option
Get the best price for Morley Red Honeywell MI-MCP-GLASS
GST Addressable Manual Call Point
Usage/Application | Fire Alarm System |
Model Name/Number | gst (DI-M9204) |
Working Voltage | Loop 24V |
Diameter | 87.1mmx87.1mmx58.5mm (with back box) |
Box Material | abs |
Color | Red |
Mounting Type | 60mm |
Connecting to the loop of GST fire alarm system, DI-M9204 Digital Manual Call Point (MCP) is suitable for public places. When there is a fire, pressing the frangible element on this MCP can send fire signal to fire alarm control panel. After receiving the signal, the control panel will show address information of the MCP and generate alarm sound.
Gst Conventional Manual Call Point
Weight | About 144g (with base) |
Usage/Application | Fire Alarm System |
Model Name/Number | C-9202 |
Working Voltage | 24VDC |
Dimensions Mm | 97mmx100mmx45.5mm |
Box Material | ABS, Red (PANTONE 193C) |
Color | Red |
Notifier Honeywell Manual Call Point
Model Name/Number | Notifier Nbg-12Lx |
Box Material | plastic |
Color | red |
Usage/Application | Fire Alarm System |
- Addressable Manual Pull Station
- Keyed Operation
- Red
- Wall Mount
System Sensor Conventional Manual Call Point
Color | RED |
Glass | YES |
Usage/Application | Fire Alarm System |
Model Name/Number | HM-MCP-GLASS |
Addressable or Conventional Fire Alarm Sounders or Hooters
System Components | Fire Alarm Control Panel |
Type | Conventional Fire Alarm Sounders |
Body Material | M S Body |
Color | Red and White |
Features | Hooter with flash |
Size | 134x115x48mm |
Morley Honeywell Addressable Heat Detector
Diameter | 51 mm installed in B501 |
Startup Time (sec) | 10 sec |
Operating Temperature | -20 DegreeC to 60 DegreeC |
System Components | heat detector |
Model Name/Number | morley Honeywell |
Type | Addressable |
Usage/Application | industrial office residential |
Weight (grams) | 170 gr. (6 oz) |
Automation Grade | Automatic |
Simplex Addressable Heat Detector
Startup Time (sec) | 10 sec |
Operating Temperature | -20 DegreeC to 60 DegreeC |
System Components | HEAT DETECTOR |
Model Name/Number | 4098-9733 |
Automation Grade | Automatic |
Fault Contact | 15 x 15 x 15 Centimeters |
- SSD HEAT SENSOR
- Replacement heat detector head for use in Simplex addressable panels
- Senses the heat or the rate-of-rise in the air temperature in the environment
- 30 Day Returns
- *12 Month Warranty
Notifier Honeywell Addressable Heat Detector
Weight (grams) | 9.6 ounces |
Diameter | 6.5 x 6.5 x 3 inches |
Startup Time (sec) | 10 sec |
Operating Temperature | -20 DegreeC to 60 DegreeC |
Model Name/Number | NH 200H |
- NOTIFIER NH-200H Heat Detector
- #1 Supplier for Fire Safety Equipment in North America. Our company is dedicated to help and supply your fire equipment needs with the best prices Worldwide.
- We have the most dedicated customer service team to help you with any question regarding our products and your orders.
- All of our products are genuine parts, brand new, sealed with original packaging and shipped from the United States of America and have 30 days return if not satisfied plus 12 months warranty.
Gst Conventional Heat Detector
Operating Temperature | -20 DegreeC to 60 DegreeC |
System Components | HEAT DETECTOR |
Type | Conventional |
Model Name/Number | DC-9103E |
Operating Voltage (VDC) | 24VDC(16VDC~28VDC) |
Weight (grams) | About 110g (with base) |
Alarm Current (mA) | less than and eqal to 55mA |
Diameter | Diameter: 100mm |
3 classes programmable. Reed switch testing. The fire LED allows 360° viewing. Output terminal for remote indicator available. Complying with EN 54-5.
Description
DC-9103E Conventional Rate of Rise and Fixed Temperature Heat Detector is a new generation product of GST. With built-in microprocessor, it works stably by being fixed with highly reliable fire judging program. On detecting a fire signal, it can change its own current to transmit the signal to fire alarm control panel (FACP) or addressable zone monitor unit. The detector keeps illuminating fire LED until it is reset by power-down
Gst Addressable HEAT Detector
Type | Conventional |
Usage/Application | FOR SAFTEY |
Model Name/Number | I9103 |
Weight (grams) | About 120g |
Alarm Current (mA) | Less Than Or Equal To 5.0 mA |
Operating Temperature | -20 DegreeC to 60 DegreeC |
System Components | HEAT DETECTOR |
Agni Coventional Heat Detector
Wall Mounted | Yes |
System Components | HEAT DETECTOR |
Type | Conventional |
Usage/Application | HEAT |
Model Name/Number | RPS0021 |
Automation Grade | Automatic |
Audible Alarm | Yes |
- Operating Voltage DC (10.8 ~ 30) V
- Surge Current (max.) 100 µA - Start-up time (max.) 60 s - Stand by current (max.) 45 µA
- Operating Temperature 0°C ~ +50°C
System Sensor Conventional Smoke Detectors
Brand | system sensor |
Usage/Application | Industrial Premises |
Color | white |
Alarm Sensor Type | Optical |
Product Type | smoke detector |
- Wide operating voltage 8 to 30VDC
- Programmable sensitivity
- Range of detector bases available
- Tested and approved to EN54 – 7:2000 (Amendment 1
- Low profile design
SYSTEM SENSOR COVENTIONAL HEAT DETECTOR
Type | Conventional |
Model Name/Number | System Sensor 5151 |
Automation Grade | Automatic |
System Components | HEAT DETECTOR |
- System Sensor 5151
- The 5151 thermal detector meets the needs for applications where rapid response is vital and rapid temperature increases would only be caused by a fire emergency.
The detector initiates an alarm in response to both rapid rate-of-rise conditions (increases in excess of 15ºF per minute) and fixed heat (135ºF). This enables the heat detector to communicate an alarm to the central control panel prior to reaching its fixed set point for high rates of rise, providing a timely response to both rapid and slow temperature increases.
System Sensor Fire Alarm Panel
Voltage | 24VDC |
Model Name/Number | SS-4ZE 4 ZONE FIRE |
Usage/Application | Industrial |
Brand | SYSTEM SENSOR |
Designed to satisfy the requirements of both installers and end users, this panel offers an advantageous combination of quick installation, enhanced feature set and advanced programming for all kinds of fire detection/fire safety applications. It is equipped with programmable relays, delay setting for alarm verification, software isolation of zone and NAC output, mapping of NAC to specific zones and password-protection
- 16 x2 LCD display
- Earth fault monitoring
- Certified for safety standard IEC 62368-1:2018
- Individual zone isolation
- One-man walk test facility
- Up to 600m per zone cable
- Event logging
- Cloud connectivity for CMS monitoring
Notifier Honeywell Fire Alarm Panel
Usage/Application | Industrial |
Brand | NOTIFIER |
Model Name/Number | NFS-320E |
The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series from Honeywell NOTIFIER. Designed specifically for small applications, this device comes with a modular design to minimise installation time, enable faster response times, and simplify maintenance. The panel can be configured with just a few devices for small buildings, or networked with many devices to protect a large campus or a high-rise office block.
- Fully field programmable
- Direct connect to NOTIFIER FirstCommand™ Emergency Communications System
- One isolated intelligent Signalling Line Circuit (SLC) Style 4, 6 or 7
- Standard 80-character LCD display
- Built-in Alarm, Trouble, Security, and Supervisory relays
System Sensor Fire Alarm Panel
GST Conventional Fire Alarm Control Panel
Model Name/Number | GST108A |
Usage/Application | Industrial |
Brand | GST |
Fire Alarm Maintenance Services
Service Location | Rajasthan |
Service Mode | Onsite |
Service Type | Maintenance Service for Fire Alarm |
Service Duration | 1-2 day |
Hochiki Addressable Fire Alarm Panel
Colour | Red (optional gray |
Model Name/Number | FN-LCD-S |
Usage/Application | Industrial |
Material | Mild Steel (MS) |
Operating Voltage | Aux 24VDC or |
Operating Current | 20mA |
Relative Humidity | 85% RH Non-Condensing |
Brand | Hochiki |
UL 864 9th Edition Listed Large 320 character liquid crystal display (8 line x 40 character) allows viewing of system status LED indicators for Fire, Supervisory Alarm, PreAlarm, Fire Output Active, AC Power On, On Test, Panel Sounder Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System Trouble & NAC Trouble Same controls as the FireNET® fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit) Up to 15 FN-LCD-S serial annunciators may be connected to a FireNET® control panel or network annunciator Resides on the FireNET® slave RS-485 line Local piezo sounder for event notification Supports user codes & firefighter key to enable access & controls Powered by FireNET® Aux 24VDC or UL fire listed Aux. 24VDC supply Available in red or gray, and can be surface or flush mounted Built-in help & alarm information screens Fire drill functio
Simplex Addressable Sounder
Model Name/Number | 49AV-WRQ |
Brand | SIMPLEX |
Material | ABS |
Usage/Application | Offices |
Body Material | Plastic |
Color | RED |
- Self-Test Mode allows on-board sensors to detect the strobe and horn output and then report their status to the control panel
- Reports are available at the control panel detailing appliance point ID, custom label, type, and candela setting
- Magnet Test diagnostics assist checkout and testing of appliances and wiring
- Access the electrical test point without removing cover
- Compatibility with legacy TrueAlert addressable systems for upgrade and replacemen
Notifier Honeywll Addressable Sounder
Operating Voltage | 15 to 28VDC |
Weight | 168g |
Material | ABS |
Color | RED |
Power Consumption | 180V to 250V AC Mains |
Body Material | Plastic |
Usage/Application | Offices |
Action Current | 50mA |
Brand | Notifier |
Model Name/Number | NFXI-WS-R |
Gst Addressable Sounder
Operating Voltage | 24VDC Loop, 24VDC Power Supply |
Humidity | 95%, non condensing |
Usage/Application | Offices |
Model Name/Number | I-9403 |
Dimensions Mm | 110mm, Height 95.9mm (shallow base) |
Body Material | Plastic |
Color | RED |
Brand | Gst |
Material | ABS |
☆ Loop powered or External 24VDC powered
☆ Switch off Light or Sound output for special applications
☆ Power saving mode or Normal mode
☆ Electronically addressed
☆ Comply with EN54-3
☆ LPCB Approved
Simplex Addressable Fire Alarm Panel
Usage/Application | Commercial |
Material | Mild Steel (MS) |
Brand | Simplex |
Colour | red |
Model Name/Number | 4007ES |
Display Type | MICROPROCESSOR |
Warranty | 12 months |
Agni Conventional SOUNDER
Current Consumption Normal Fire | 150 mA |
Brand | AGNI SURAKSHA |
Material | Plastic |
Operating Voltage | 24 V DC |
Model Name/Number | H-ABS -5 |
Weight | 250 GRAMS |
Color | Red,Silver |
Dimensions Mm | 13 x 8 x 21 Centimeters |
Usage/Application | INDUSTRIAL , COMMERCIAL ,DOMESTIC |
Power Source | DC/Battery |
- Material: Plastic Stainless Steel, color: red
- Strobe / Hooter with Flasher for Conventional Fire Alarm System comes with flashing LED light,
- Package contents: 1 of 24v, hooter/Voltage Range: DC 24Vr
- High Sound output / Light Source
- The siren will send out both loud sound and quick flash light to remind people escape from the fire.
Morley Honeywell Addressable Multi-Sensor Detector
Brand/Company | Morley |
Usage/Application | Industrial Premises |
Detection Principle | optical & thermal |
Operating Voltage | +15 to +32Vdc |
Automation Grade | Automatic |
Alarm Sensor Type | Optical |
Body Material | ABS Plastic |
Material | abs |
Startup Time (sec) | 10 sec |
Color | white |
Agni Addressable Fire Alarm Control Panel
Brand | Agni |
Dimension | (420X325X120)MM. |
Weight | 10 KG APPROX.. |
Model Name/Number | 4 ZONE FIRE ALARM CONTROL PANEL |
Power | 15.6MA/ZONE ALARM CURRENT |
Usage/Application | Industrial |
Operating Voltage | 24 DC+ 10% |
The panel operates on 220 V AC Mains with 24 V DC Battery as a stand by power ,
The built in circuit provide constant voltage charging to maintain the battery capacit
Gst Addressable Fire Alarm Panel
Dimension | 420mm(W)x580mm(H)x202mm(D) |
Model Name/Number | GST200-2 |
Brand | gst |
Power | elecctric |
Usage/Application | Industrial |
Material | Mild Steel (MS) |
Colour | black |
Shape | Ractangle |
SYSTEM SENSOR CONVENTIONAL SOUNDER
Usage/Application | INDUSTRIAL COMERCIAL |
Operating Voltage | 17V to 32V DC |
Sound Output | 87dB to 100dB |
Temperature | -10 to +55 |
Brand | SYSTEM SENSOR |
Agni Conventional Smoke Detector
Alarm Sensor Type | Optical |
Product Type | SMOKE DETECTOR |
Brand | AGNI |
Usage/Application | Industrial Premises |
Color | Red |
Automation Grade | Automatic |
- Optical smoke sensor Type
- Multi Sensor Type
- Red Led Blinking Normal Mode and InRo case Led Permanent Operated
Agni Conventional Fire Alarm Panel
Model Name/Number | Agni 4 Zone Fire Alarm Panel |
Power | Battery Powered |
Display Type | 16X2 Character LCD Display Facility |
Weight | 2 KilogramS |
Alarm Output | Audible |
Usage/Application | Industrial |
Brand | AGNI SURAKSHA |
- Trickle & fast charging facility
- Over Load, Short Circuit
- The system is a mechanical or electrical means of warning everyone once a fire has been detected
- Protected From Hi Voltage
- Suitable for Mall, Bank, Restaurant etc, Suitable for sound polluted areas
Fire Beam Detector
An optical beam smoke detector is a device that uses a projected beam of light to detect smoke across large areas, typically as an indicator of fire.They are used to detect fires in buildings where standard point smoke detectors would either be uneconomical or restricted for use by the height of the building. Optical beam smoke detectors are often installed in warehouses as a cost effective means of protecting large open spaces